UNI-T UT207B Digital Clamp Meter

3,450.00 EGP

UNI-T UT207B Digital Clamp Meter

UNI-T UT207B – is an auto ranging True RMS digital clamp meter equipped with a large 6000-count LCD. This clamp meter measures AC/DC current, AC/DC voltage, resistance, capacitance, duty cycle, continuity, and may be used for diode testing.

UT200 series are 6000-count digital clamp meters with auto range, large LCD, true RMS, auto scale memory, and NCV functions. They conform to CAT III 1000V/CAT IV 600V safety rating and certified by CE/ETL. The UT206B, UT207B, and UT208B come with Loz mode for eliminating ‘ghost ’voltage, LPF ACV function for measuring INV and VFD voltage, and inrush current mode for capturing transient current. 
UT207B Features:
  • Flashlight button: short press this button to turn on/off the flashlight.
  •  Flexible current probe (optional) to extend the AC current measurement range to3000A.
  • Inrush current capture.
  • NCV Multi-Segment Display and audio/visual alarm.
  • True RMS/Auto backlight.
  • NCV/Function retention.

Available on backorder

SKU: UT-20071 Categories: ,

Description

UNI-T UT207B Digital Clamp Meter

Features

  • Functions:
    • AC/DC current.
    • AC/DC voltage.
    • inrush current.
    • resistance.
    • LoZ ACV.
    • capacitance.
    • duty cycle.
    • NCV.
    • continuity.
    • diode testing.
  • Auto ranging.
  • Built-in flashlight.
  • True RMS.
  • ZERO mode.
  • Relative mode.
  • Data hold.
  • Automatic backlight.
  • Auto power off.
  • Low battery indication.
  • MAX/MIN mode.
  • Auto Sleep and Wake Up function.

Technical Specifications

Function Range Accuracy
AC current 1000 A ± (2% 5)
DC current 1000 A ± (2% 5)
AC current frequency response 40 Hz~400 Hz
Inrush current 1000 A ± (10% 10)
AC voltage 6 V ± (1.2% 3)
60 V/600 V/1000 V ± (1% 8)
DC voltage 600 mV ± (0.8% 3)
6 V/60 V ± (0.5% 5)
600 V ± (0.5% 5)
1000 V ± (0.5% 5)
Low pas filter (LPF ACV) 600 V/1000 V ± (2% 5)
AC voltage frequency response 40 Hz~400 Hz
LoZ ACV 600 V/1000 V ± (2% 5)
Resistance 600 Ω ± (1% 3)
6 kΩ/60 kΩ/600 kΩ ± (1% 2)
6 MΩ/60 MΩ ± (2% 8)
Capacitance 60 nF ± (4% 25)
600 nF/6 μF/60 μF/60 000 μF ± (4% 5)
6 mF/60 mF ± (10% 9)
Low voltage frequency  10 Hz~1 MHz ± (0.1% 3)
Duty cycle 10%~90% ± (2.6% 7)

General Specifications

Display LCD, 6000 count, 43 mm × 45 mm.
Power 1.5V battery (R03) × 3 pcs.
Jaw opening 42 mm.
Current frequency 50 Hz~60 Hz
Analog bar 31 segment
Input impedance ≥10 MΩ
Dimensions 272 mm × 81 mm × 43.5 mm
Weight 420 g

 

package included:

1 X UNI-T UT207B Digital Clamp Meter.

Electra